Considerations To Know About perkinelmer autosampler
Considerations To Know About perkinelmer autosampler
Blog Article
Mixing by aspiration—mixing of sample by aspiration as an alternative to shaking makes certain homogeneity in the sample and maintains cell viability
The CytKick Max Autosample contains a Strengthen manner that allows faster sample processing, as well as passive cooling for many plates/racks. A CytKick Max Accessory Kit is integrated which contains four accent plates: two cooling plates and two tube adaptors, as well as a Max dongle important. A pc just isn't provided Together with the autosampler due to the fact one particular is provided with the cytometer.
To avoid probe crashes, which may involve highly-priced probe substitute, the CytKick Max Autosampler mechanically performs a probe self-calibration to help make certain reliable positioning of your probe inside each and every very well. The self-calibration verifies good functionality of the probe, decreases variability in probe positioning after some time to circumvent failures during plate operates, and allows improve trustworthiness around the lifetime of the technique.
Contrary to other plate loaders that mix samples by shaking, which can not assure homogeneity on the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing even though preserving sample viability and resulting in constant details with CVs fewer than 10% through the plate. The CytKick Max Autosampler also has a mild blend method for fragile cell traces.
The autosampler’s indicator lights and warning units are intended making sure that a consumer who has walked faraway from the technique can easily see the procedure standing all the time.
To take care of system overall flexibility, the handbook sample probe is always obtainable regardless if the loader is present, and switching involving tubes and plates is detected via software and will not have to have additional user intervention.
The CytKick Max Autosampler was meant to reduce technique down time. Automated sampling equipment are sometimes stricken by clogging or probe crashes. The Clever Probe, perkinelmer autosampler using a 200-micron diameter that's greater than most probes offered from the field, minimizes scenarios of clogging.
The intuitive software allows brief Mastering and knowledge analysis. For example, a warmth map view makes it possible for quick screening and affirmation of samples whilst the instrument is buying information.
Quick transition—no disassembly, no supplemental QC, no reboot necessary for conversion concerning plates and tubes
The CytKick Max Autosampler has two selections for processing samples in the large-throughput atmosphere: superior-throughput mode and Improve method.
Self-calibration of your probe also allows the autosampler for being simply moved, so it could be shared amongst a number of instruments.
The instrument layout and software package have been produced with client relieve-of-use in mind. The CytKick Max Autosampler has fluidic bottles with sensors that tell the person once the fluids need to be replaced.
Autocleaning of autosampler is finished in the course of the instrument shutdown method therefore no more user methods are necessary to keep up procedure.
Creating an experiment While using the Attune NxT cytometric software program is easy. Utilizing a plate format perspective, customers can make payment wells, determine instrument configurations, and identify samples.